BFB-3000 Set Up and Operations Manual
6.9.2 Extruder control
Make sure all extruders are loaded.
Use ‘Manual move’ (page 18) to move the extruders to the centre of the machine,
and lower the bed. This makes it easy to clean any purged material.
On the control panel select the ‘Extruder control’ function and press enter:
‘Extruder control’ manages one extruder at a time (E1, E2 or E3) using the buttons on
the control panel.
“>” indicates
selected extruder
E1, E2 or E3 are
selected using
the Z buttons
Temperature
at extruder
nozzle (°C)
Target
temperature
at extruder
nozzle (
°C).
Revolutions per
minute for the
extruder drive
screw. Use X
buttons to
change.
Extruder motor
will not turn until
target
temperature has
been achieved.
“*” indicates
extruder is being
heated.